Quantitative antimicrobial susceptibility testing of Haemophilus influenzae and Streptococcus pneumoniae by using the E-test

Author:

Jorgensen J H1,Howell A W1,Maher L A1

Affiliation:

1. Department of Pathology, University of Texas Health Science Center, San Antonio 78284-7750.

Abstract

The E-test (PDM Epsilometer; AB Biodisk, Solna, Sweden) is an antimicrobial agent gradient-coated plastic test strip which allows MIC determinations on agar media. The test is performed in a manner similar to the agar disk diffusion procedure. A collection of Haemophilus influenzae and Streptococcus pneumoniae strains possessing various resistance mechanisms was used to evaluate the E-test method. H. influenzae strains were tested with both Haemophilus test medium (HTM) and PDM ASM II chocolate agar, while the S. pneumoniae strains were tested on Mueller-Hinton sheep blood agar. E-test MICs for a total of 10 antimicrobial agents were compared with broth microdilution MICs determined according to National Committee for Clinical Laboratory Standards methods. In general, E-test MICs for both species were quickly and easily interpreted and agreed within one log2 MIC increment in 89.8% of tests with H. influenzae and in 80.4% of pneumococcal tests. The majority of disagreements between the E-test and conventional MICs occurred with trimethoprim-sulfamethoxazole because of trailing and diffuse E-test MIC endpoints with both species. Ampicillin MICs for beta-lactamase-producing H. influenzae determined by the E-test differed at times from those determined by conventional testing because of the vagaries of interpreting colonies growing within the E-test inhibition ellipses. E-test penicillin MICs for pneumococci tended to be 1 to 2 log2 dilutions lower than those determined by using Mueller-Hinton broth supplemented with lysed horse blood. Nevertheless, strains of both species with documented resistance to the study drugs were detected by E-tests, i.e., 0.7% of the tests had very major errors with H. influenzae and 0.8% had very major errors with S. pneumoniae. Thus, the E-test represents a potential alternative method for antimicrobial susceptibility testing of these two fastidious bacterial species.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 111 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3