Detection of Circulating Aspergillus fumigatus DNA by Real-Time PCR Assay of Large Serum Volumes Improves Early Diagnosis of Invasive Aspergillosis in High-Risk Adult Patients under Hematologic Surveillance

Author:

Suarez F.1,Lortholary O.23,Buland S.4,Rubio M. T.1,Ghez D.1,Mahé V.5,Quesne G.4,Poirée S.6,Buzyn A.1,Varet B.1,Berche P.4,Bougnoux M. E.4

Affiliation:

1. Université Paris Descartes, Faculté de Médecine, Departments of Haematology

2. Infectious and Tropical Diseases, Centre d'Infectiologie Necker-Pasteur

3. Centre National de Référence Mycologie et Antifongiques, CNRS URA 3012, Institut Pasteur, Paris, France

4. Microbiology, Hôpital Necker-Enfants Malades

5. Intensive Care Medicine

6. Radiology

Abstract

ABSTRACT Detection of galactomannan antigen (GMA) in serum is the standard assay for the diagnosis of invasive aspergillosis (IA) in high-risk patients with hematological disorders. Detection of Aspergillus DNA in serum has been proposed, but its sensitivity is lower than that of GMA when small serum volumes (SSV) are used. In this study, we investigated whether extraction of DNA from large serum volumes (LSV) improves diagnostic yield. In a 13-month prospective study, we compared the performances of twice-weekly screening of serum for GMA by an enzyme immunoassay and weekly screening for Aspergillus fumigatus DNA by a real-time PCR (RT-PCR) assay of 1.0 ml (LSV) or 100 μl (SSV) of serum. We included 124 patients (138 treatment episodes), with 17 episodes of EORTC (European Organization for Research and Treatment of Cancer)/MSG (Mycoses Study Group)-documented IA. In all, 1,870 samples were screened for GMA. The sensitivity (Se), specificity (Sp), and positive and negative predictive values (PPV and NPV, respectively) of GMA for IA were 88.2%, 95.8%, 75%, and 98.3%, respectively. We screened 938 samples for Aspergillus DNA by using LSV; 404 of these samples were also tested with SSV. The Se, Sp, PPV, and NPV of RT-PCR were 100%, 96.7%, 81%, and 100%, respectively, with LSV and 76.5%, 96.7%, 81.3%, and 95.6%, respectively, with SSV. DNA detection gave a positive result when performed on LSV in two cases of IA where the GMA assay result remained negative. Furthermore, in four IA cases, DNA was detected earlier than GMA. The use of LSV for extraction improved the performance of the RT-PCR, which appears highly sensitive and specific for the early diagnosis of IA in high-risk patients with hematological disorders.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3