Recovery of Poliovirus from Turbid Estuarine Water on Microporous Filters by the Use of Celite

Author:

Hill William F.12,Akin Elmer W.12,Benton William H.12,Mayhew Charles J.12,Metcalf Theodore G.12

Affiliation:

1. Office of Research and Development, National Environmental Research Center, Water Supply Research Laboratory, Cincinnati, Ohio 45268

2. Department of Microbiology, University of New Hampshire, Durham, New Hampshire 03824

Abstract

The application of a new step for recovering poliovirus from moderately to highly turbid estuarine water by the filter virus-adsorption technique was investigated. The experiments were conducted under both (i) laboratory-based conditions (200-ml volumes) where the turbidity was controlled and (ii) simulated field conditions (15- to 100-gal volumes) where the turbidity varied depending upon the hydrology of the raw estuarine water. The new step consisted of adding Celite to the turbid water prior to sampling for virus. In the experiments, the pH of the water was first adjusted to 3.5 and then AlCl 3 was added to 0.0005 M. Celite was added to a concentration of 0.01% and mixed thoroughly. Either an HE Cox M-780 microfilter (Cox Instrument, Div. of Lynch Corp., Detroit, Mich.) or an MF-membrane filter (Millipore Corp., Bedford, Mass.) was used as the virus adsorbent. Virus was eluted from the Celite-filter complex in situ at pH 9 with 5× nutrient broth. In the laboratory-based experiments, when turbidity ranged from 5.0 to 30.0 Jackson turbidity units (JTU), virus recovery ranged from 66 to 89%. In the simulated field experiments, when the turbidity ranged from 8.5 to 80.0 JTU, virus recovery ranged from <1 to 74%, depending upon the multiplicity of virus input and the level of turbidity. The new step greatly improved the filtration-flux of turbid water and significantly reduced the premature clogging problem usually observed with microporous filters.

Publisher

American Society for Microbiology

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Reference19 articles.

1. Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters;Berg G.;Appl. Microbiol.,1971

2. Rapid quantitative method for Salmonella detection in polluted waters;Cheng C. M.;Appl. Microbiol.,1971

3. Factors in the membrane filtration of enteroviruses;Cliver D.;Appl. Microbiol.,1955

4. Viral hepatitis in New;Dougherty W. J.;Jersey. Amer. J. Med.,1962

5. Effect of plaque assay diluent upon enumeration of poliovirus type 1;Hamblet F. E.;Appl. Microbiol.,1967

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3