Enumeration of Bacterial Cell Numbers and Detection of Significant Bacteriuria by Use of a New Flow Cytometry-Based Device

Author:

Okada Hiroshi1,Shirakawa Toshiro2,Gotoh Akinobu2,Kamiyama Yutaka1,Muto Satoru1,Ide Hisamitsu1,Hamaguchi Yukio3,Horie Shigeo1

Affiliation:

1. Department of Urology, Teikyo University School of Medicine, Tokyo, Japan

2. Division of Clinical Genetics and Gene Therapy, Kobe University Graduate School of Medicine

3. The Sysmex Corp., Kobe, Japan

Abstract

ABSTRACT A new, automated flow cytometry-based urine bacterium analyzer (UBA) was developed. We assessed the UBA for linearity of measurement, reproducibility of results, carryover rate, and correlation of measured results with those determined by urine culture. We also evaluated its ability to screen urine samples for significant bacteriuria. The UBA showed excellent linearity and a minor carryover rate. Results from the UBA were highly reproducible, and in between-run precision assays, the coefficients of variation for the UBA results were smaller than those for the urine culture results. Two hundred seventy-three urine specimens from patients attending the outpatient clinics of two university-based hospitals were examined. The results for the UBA were compared with those for urine culture. The UBA detected significant bacteriuria with a sensitivity of 96.6%, a specificity of 79.9%, a positive predictive value of 57.0%, a negative predictive value of 98.8%, a false-positive rate of 15.8%, a false-negative rate of 0.7%, and an accuracy of 83.5%. These results were comparable to or better than those obtained with previously reported screening procedures. The UBA can perform accurate enumeration of bacterial cells automatically in 90 seconds and can be used for the screening of significant bacteriuria.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference11 articles.

1. Barlett, R. C., D. A. Zern, I. Ratkiewicz, and J. Z. Tetreault. 1992. Screening for urinary tract infection with the Yellow IRIS. Lab. Med.23:599-602.

2. Ben-Ezra, J., L. Bork, and R. A. McPherson. 1988. Evaluation of the Sysmex UF-100 automated urinalysis analyzer. Clin. Chem.44:92-95.

3. Bowman, R. A., and T. V. Riley. 1991. Evaluation of Clinitek 200 and RapimatI/T for screening for urinary tract infection. J. Clin. Pathol.44:58-60.

4. Simplified Technique for Detection of Significant Bacteriuria by Microscopic Examination of Urine

5. Cintron, F. 1992. Initial processing, inoculation, and incubation of aerobic bacteriology specimens. Section 1.4.10-1.4.11. In H. D. Isenberg (ed.), Clinical microbiology procedures handbook. American Society for Microbiology, Washington, D.C.

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3