Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques

Author:

McLaughlin J C,Hamilton P,Scholes J V,Bartlett R C

Abstract

The lysis-centrifugation technique (ISOLATOR; E. I. du Pont de Nemours & Co., Wilmington, Del.) and the radiometric blood culture technique (BACTEC; Johnston Laboratories, Inc., Cockeysville, Md.) were compared on 1,000 blood cultures. A total of 16 ml of blood was distributed: 8 ml into an ISOLATOR 7.5 microbial tube and 4 ml each into BACTEC 7C and 8B bottles. The concentrate from the ISOLATOR tubes was inoculated under a laminar-flow hood onto two sheep blood agar plates (one incubated in CO2 and one incubated anaerobically), one chocolate agar plate, and one brain heart infusion agar plate. Of 91 blood specimens obtained that yielded clinically significant organisms, 52 were positive by both systems, 27 were positive by the ISOLATOR system only, and 12 were positive by the BACTEC system only. From the positive blood specimens, 97 clinically significant organisms were isolated: 57 by both systems, 27 by the ISOLATOR system only, and 13 by the BACTEC system only. Of the 57 organisms detected by both systems, 28 were detected simultaneously, 13 were detected earlier by the ISOLATOR system, and 16 were detected earlier by the BACTEC system. Isolated colonies were obtained earlier by the ISOLATOR system in 40 cases and by the BACTEC system in 5 cases. Organisms determined to be contaminants by thorough chart review were isolated from 138 ISOLATOR tubes. In 98 instances, these were represented by one colony of Staphylococcus epidermidis, alpha-hemolytic streptococci, or diphtheroids. The ability to determine CFU per milliliter with the ISOLATOR system did not help differentiate clinically significant organisms from contaminants.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference3 articles.

1. Improved blood culture technique based on centrifugation: clinical evaluation;Dorn G. L.;J. Clin. Microbiol.,1979

2. Isenberg H. D. 1983. Clinical laboratory comparison of the lysis-centrifugation blood culture technique with radiometric and broth approaches p. 38-54. In A. Balows and A. Sonnenwirth (ed.) Bacteremia: laboratory and clinical aspects. Charles C Thomas Publishers Springfield Ill.

3. Evidence for transient Staphylococcus epidermidis bacteremia in patients and in healthy humans;Zierdt C. H.;J. Clin. Microbiol.,1983

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3