Rapid Detection of a Schistosoma mansoni Circulating Antigen Excreted in Urine of Infected Individuals by Using a Monoclonal Antibody

Author:

Attallah Abdelfattah M.12,Ismail Hisham1,El Masry Samir A.2,Rizk Hassan3,Handousa Aia4,El Bendary Mahmoud3,Tabll Ashraf1,Ezzat Farouk2

Affiliation:

1. Biotechnology Research Center, New Damietta City,1 and

2. Gastro-Enterology Center2 and

3. Internal Medicine3 and

4. Parasitology Departments,4 Faculty of Medicine, Mansoura University, Mansoura, Egypt

Abstract

ABSTRACT Schistosoma circulating antigens were used to indicate the infection intensity and to assess cure. An immunoglobulin G2a (IgG2a) mouse monoclonal antibody was used in a fast dot-enzyme-linked immunosorbent assay (ELISA; FDA) for rapid and simple diagnosis of schistosomiasis in the field. Seven hundred Egyptians were parasitologically examined for Schistosoma mansoni and other parasitic infections. A rectal biopsy was done as a “gold standard” for individuals showing no S. mansoni eggs in their feces. Egg counts were obtained by the Kato smear method for only 100 of 152 individuals with eggs in their feces. Specific anti-schistosome IgG antibodies were evaluated in sera by ELISA. Urine samples from the 700 individuals were tested by FDA for detection of the circulating antigen. The assay showed a sensitivity of 93% among 433 infected individuals and a specificity of 89% among 267 noninfected individuals. FDA showed the highest efficiency of antigen detection (91%) compared with the efficiency of antibody detection by ELISA (75%) and stool analysis (60%). In addition, FDA detected infected patients with 20 eggs/g of feces. Also, the sensitivity of FDA ranged from 90 to 94% among samples from patients with different clinical stages of schistosomiasis. All the assay steps can be completed within 30 min at room temperature for 96 urine samples. The monoclonal antibody identified a 74-kDa antigen in different antigenic extracts of S. mansoni and Schistosoma haematobium and in the urine of infected individuals. In addition, a 30-kDa degradation product was identified only in the urine samples. On the basis of these results, FDA should be used as a rapid tool for the sensitive and specific diagnosis of Schistosoma infection.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3