Bacterial colonization and endotoxin content of a new renal dialysis water system composed of acrylonitrile butadiene styrene

Author:

du Moulin G C,Coleman E C,Hedley-Whyte J

Abstract

We measured endotoxin and bacterial levels in tap water, in water purified by reverse osmosis, and in dialysate samples over a 4-month period in a new 10-bed renal dialysis unit. Water treated by reverse osmosis is conducted to the 10 stations through 111 m of piping composed of acrylonitrile butadiene styrene (ABS). All determinations were made prior to the opening of the unit and after the system was purged for 35 h with all bedside station taps open. Formaldehyde disinfection of the piping system was attempted with a recommended protocol after 11 weeks by feeding 2.5 liters of 37% formaldehyde (0.85%, vol/vol) into the delivery system. Prior to water purging, 24 ng of endotoxin per ml was detected. This level decreased to 2.0 ng of endotoxin after the purging. Levels of endotoxin remained below 1.0 ng of endotoxin per ml throughout the duration of the study. In contrast, the level of viable microorganisms recovered from the treated water was approximately 3.5 X 10(4) CFU/100 ml. Even after disinfection of the system, there was no significant decrease in culturable bacteria from the water even though endotoxin levels were lower. Species isolated from the renal dialysis system were predominately pseudomonads, whereas species isolated from the tap water were Bacillus and Flavobacterium species. ABS provides a surface suitable for long-term colonization and growth of bacteria. Currently recommended decontamination protocols are ineffective in removing potentially pathogenic bacteria from ABS pipes and thus constitute an increased risk to patients undergoing dialysis.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference13 articles.

1. Association for the Advancement of Medical Instrumentations. 1984. American national standard for hemodialysis systems p. 273-296. In AAMI standards and recommended practices. Association for the Advancement of Medical Instrumentation Arlington Va.

2. In vivo studies of dialysis-related endotoxemia and bacteremia;Bernick J. J.;Nephron,1981

3. Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers;Bolan G.;J. Infect. Dis.,1985

4. Occupational exposure to formaldehyde in dialysis units;Centers for Disease Control.;Morbid. Mortal. Weekly Rep.,1986

5. Bacteremia associated with reuse of disposable hollow-fiber hemodialyzers;Centers for Disease Control.;Morbid. Mortal. Weekly Rep.,1986

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3