Optimal Time of Extraction Retrievable Inferior Vena Cava Filters in Venous Thromboembolic Treatment: Evidence Based Case Report

Author:

Muradi Akhmadu1,Hermansyah Rudi2

Affiliation:

1. Division of Vascular and Endovascular Surgery, Department of Surgery, Faculty of Medicine, University of Indonesia,Dr. Cipto Mangunkusumo National Centra Hospital, Jakarta, Indonesia

2. Department of Surgery, Faculty of Medicine, Universitas Indonesia, Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia

Abstract

Background: Inferior vena cava (IVC) filters have been proven to be significantly advantageous and clinically efficacious in the prevention of deathly venous thromboembolism, but also carry long-term risks, such as device failure, filter fracture, migration, penetration into adjacent structures, etc. Retrievable filters offer the same degree of protection, and subsequently lower those risk by removing them after they aren’t needed. Unfortunately, increasing use of retrievable filters leads to one alarming trend: there’s massive number of filters that are left for an extended time. Whether the time between deployment and retrieval affects filter’s technical success of retrieval remains questionable. Here is a case of a 45-year old woman who had undergone retrievable IVC filter due to pulmonary embolism risk. The patient only came to clinician for routine follow- up once, one month after deployment. One year later, the patient felt abdominal pain and asked to remove the filter. After one failed attempt, the clinician decided to leave the filter in situ as permanent filter. Method: Literature searching was conducted in several databases (ScienceDirect, EbscoHost, and ClinicalKey) using specified keywords. Six articles that had been passed exclusion and inclusion criteria, were eventually appraised and extracted. Results: Of all six articles that are included in this study, there are no standard time of retrieval. Each study provides data regarding their attempted retrieval, successful retrieval, and dwell time. Only two articles (Uberoi et al and Glocker et al) analyze the relationship between time of retrieval and successful retrieval. Uberoi et al claims filter retrieval statistically more successful if the dwell time is less than 9 weeks, whereas Glocker et al states the procedure is considerably more successful within 3-4 months (117 days) after deployment. The reasons of retrieval failure in these studies are varied, including device angulation, filter incorporation with IVC wall, and penetration to IVC wall and adjacent structures, or significant thrombus inside the filter. Conclusion: There are no standard time of retrieval, but clinicians could follow FDA recommendation by removing the filter when it isn’t necessarily needed. However, a time span of 3-4 months between implantation and retrieval can be respectable choice to make sure the maximum chance at retrieval success.

Publisher

The Indonesian Society for Vascular and Endovascular Surgery - INASVS

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3