Outcomes of Humeral Allograft-Prosthetic Composites with Plate Fixation in Revision Total Elbow Arthroplasty

Author:

Cheema Adnan N.1ORCID,Conyer Ryan T.1ORCID,Triplet Jacob J.1ORCID,O’Driscoll Shawn W.1,Morrey Mark E.1ORCID,Sanchez-Sotelo Joaquín1ORCID

Affiliation:

1. Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota

Abstract

Background: Traditionally, the reconstruction of severe distal humeral bone loss at the time of revision total elbow arthroplasty (TEA) has used allograft-prosthetic composites (APCs) stabilized with cerclage wires or cables. We have migrated to plate fixation when revision TEA using a humeral APC is performed. This study shows the outcomes of patients treated with a humeral APC with plate fixation during revision TEA. Methods: Between 2009 and 2019, 41 humeral APCs with plate fixation of distal humeral allograft to the native humerus were performed in the setting of revision TEA. There were 12 male patients (29%) and 29 female patients (71%), with a mean age of 63 years (range, 41 to 87 years). The mean allograft length was 12 cm. All elbows had a minimum follow-up of 2 years (mean follow-up, 3.3 years). Patients were evaluated for visual analog scale pain scores, range of motion, the ability to perform select activities of daily living, and the Mayo Elbow Performance Score (MEPS). Outcomes including reoperations, complications, and revisions were noted. The most recent radiographs were evaluated for union at the allograft-host interface, failure of the plate-and-screw construct, or component loosening. Results: The mean postoperative flexion was 124° (range, 60° to 150°) and the mean postoperative extension was 26° (range, 0° to 90°); the mean arc of motion was 99° (range, 30° to 150°). The mean MEPS was 58 points (range, 10 to 100 points). Two surgical procedures were complicated by neurologic deficits. The overall reoperation rate was 14 (34%) of 41. Of the 33 patients with complete radiographic follow-up, 12 (36%) had evidence of nonunion at the allograft-host interface with humeral component loosening, 1 (3%) had evidence of partial union, and 1 (3%) had ulnar stem loosening. Conclusions: Revision TEA with a humeral APC using compression plating was successful in approximately two-thirds of the elbows. Further refinement of surgical techniques is needed to improve union rates in these complex cases. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3