Affiliation:
1. Department of Orthopaedic Surgery & Sports Medicine, Detroit Medical Center, Detroit, Michigan
Abstract
Case:
Unstable pelvic ring fractures in pregnancy are an uncommon injury. Successful treatment of these patients with an INFIX device is even less common, with sparse literature to document the patient outcomes. We found no literature documenting the acute management of a pregnant patient with an INFIX device with (1) dynamic changes recorded, such as increasing pubic symphysis diastasis, and (2) restoration of normal symphyseal anatomy after birth and INFIX removal.
Conclusion:
Use of a pelvic INFIX during pregnancy allowed functional independence. The construct offered sufficient stability while also allowing for pubic symphysis diastasis. After parturition, she returned to normal function with no injury sequela.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献