Single-Stage Press-Fit Osseointegration of the Radius and Ulna for Rehabilitation After Trans-Forearm Amputation

Author:

Hoellwarth Jason S.1ORCID,Tetsworth Kevin2ORCID,Al Muderis Munjed3ORCID

Affiliation:

1. Osseointegration Limb Replacement Center, Limb Lengthening and Complex Reconstruction Service, Hospital for Special Surgery, New York, NY

2. Department of Orthopaedic Surgery, Royal Brisbane and Women’s Hospital, Brisbane, Queensland, Australia

3. Limb Reconstruction Centre, Macquarie University Hospital, Macquarie University, Sydney, New South Wales, Australia

Abstract

Background: Upper limb (UL) amputation is disabling. ULs are necessary for many domains of life 1 , and few effective motor and sensory replacements are accessible 2 . Approximately 41,000 people in the United States have UL amputation proximal to the fingers 3 , two-thirds of (all) traumatic amputations are UL 4 , and 80% of UL amputations are performed for trauma-related etiologies 5 . Socket prosthesis (SP) abandonment remains high because of the lack of sensation, limited prosthesis control, perceived weight, and difficulty comfortably wearing the SP 6 . Transcutaneous osseointegration 7,8 surgically inserts a bone-anchored implant, passed through a transcutaneous portal to attach a terminal device, improving amputee rehabilitation by reducing perceived weight, conferring osseoperception 9 , and increasing wear time 10 . Without the socket, all residual skin and musculature remain available for transcutaneous myoelectrodes. The present article describes single-stage radius and ulna press-fit osseointegration (PFOI) after trans-forearm amputation. Description: This technique resembles a lower-extremity PFOI 11,12 . Importantly, at-risk nerves and vessels are different, and implant impaction must be gentler as a result. The surgery is indicated for patients who are dissatisfied with SP rehabilitation or declining alternative rehabilitative options, and who are motivated and enabled to procure, train with, and utilize a forearm prosthesis. An engaged prosthetist is critical. Surgical steps are exposure, bone-end and canal preparation, first implant insertion (in the operative video shown, in the radius), purse-string muscle closure, confirmation that radius-ulna motion remains, performing the prior steps for the other bone (in the video, the ulna), and closure (including potential nerve reconstruction, soft-tissue contouring, and portal creation). Although the patient in the operative video did not require nerve procedures to address pain or to create targets for transcutaneous myoelectrodes, targeted muscle reinnervation or a regenerative peripheral nerve interface procedure could be performed following exposure. Alternatives: Alternatives include socket modification, bone lengthening and/or soft-tissue contouring 13 , Krukenberg-type reconstructions 14 , or accepting the situation. An alternative implant is a screw-type osseointegration implant. Our preference for press-fit implants is based on considerations such as our practice’s 12-year history of >1,000 PFOI surgeries; that the screw-type implant requires sufficient cortical thickness for the threads 15 , which is compromised in some patients; the lower cost per implant; that the procedure is performed in 1 instead of 2 surgical episodes 15,16 ; and the documented suitability of press-fit implants for patients with challenging anatomy or comorbidities 17–19 . Rationale: PFOI can be provided for amputees having difficulty with socket wear. PFOI usually provides superior prosthesis stability, which can confer better prosthesis control versus nonoperative and other operative options in patients expressing dissatisfaction for reasons such as those mentioned above, or for poor fit, compromised energy transfer, skin pinching, compression, and abrasions. For patients who want myoelectric control of their prosthesis but who are unable because the optimal myoelectric location is obstructed by the socket, osseointegration may provide access for the electrodes by eliminating the socket. Expected Outcomes: Only 3 trans-forearm osseointegration 20–22 publications totaling 10 limbs could be identified, limiting the ability to determine generalizable outcomes. Osseointegrated prostheses, being skeletally anchored, feel lighter to patients than SPs, which should confer better outcomes. In 1 patient, multiple implant fractures and infection prompted additional surgeries. Periprosthetic bone fractures and non-infectious loosening have not been documented for UL osseointegration. Important Tips: Osseointegration eliminates the socket, relieving socket-based pain. However, neurogenic pain relief requires specific nerve procedures.Osseointegration provides a prosthesis connection. Nerve- or muscle-based prosthesis control requires separate, potentially integrated planning.Osseointegrated prostheses confer osseoperception (i.e., mechanical force transmission), not “normal” skin-mediated afferent sensation (i.e., light touch, temperature, pain) or native proprioception.Prostheses must be individualized to the patient’s elbow flexion and radioulnar rotation. An attentive prosthetist must be ensured preoperatively.Achieving the demonstrated outcomes requires more therapy and retraining than walking with an osseointegrated lower-extremity prosthesis. Patients must expect at least several months of spending multiple hours daily engaging in self-directed rehabilitation.Prosthesis utilization decision aids 23 may minimize non-beneficial surgeries. Acronyms and Abbreviations: UL = upper limbSP = socket prosthesisPFOI = press-fit osseointegrationperi-pros fx = periprosthetic fractureMRI = magnetic resonance imagingCT = computed tomography

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference21 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3