Ten-Year Outcomes of Second-Generation, All-Inside Meniscal Repair in the Setting of ACL Reconstruction

Author:

Wright Rick W.1ORCID,Huston Laura J.1ORCID,Haas Amanda K.2ORCID

Affiliation:

1. Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee

2. Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri

Abstract

Background: Meniscal repair is the goal, whenever possible, for the treatment of meniscal injury. The purpose of this study was to evaluate the long-term clinical success of meniscal repair performed with a second-generation, all-inside repair device with a concomitant anterior cruciate ligament (ACL) reconstruction. Methods: This was a retrospective review of prospectively collected patients who underwent meniscal repair by a single surgeon using the all-inside FAST-FIX Meniscal Repair System (Smith & Nephew) in conjunction with a concurrent ACL reconstruction. Eighty-one meniscal repairs (81 patients) were identified: 59 medial repairs and 22 lateral repairs. Clinical failure was defined as repeat surgical intervention involving resection or revision repair. Clinical outcomes were assessed with the Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) score, and Marx Activity Rating Scale score. Results: Ten-year follow-up was obtained for 85% (69) of 81 patients. Nine patients (13% of 69) underwent a failed meniscal repair (6 medial, 3 lateral), corresponding to a failure rate of 12% (6 of 50) for medial repairs and 16% (3 of 19) for lateral repairs. The mean time to failure was 2.8 years (range, 1.2 to 5.6 years) for the medial repairs and 5.8 years (range, 4.2 to 7.0 years) for the lateral repairs (p = 0.002). There was no difference in mean patient age, sex, body mass index, graft type, or number of sutures utilized between successful repairs and failures. Postoperative KOOS and IKDC outcome scores significantly improved over baseline scores (p < 0.001). There was no significant difference in patient-reported outcomes at 10 years between the group with successful repairs and those who had a failed repair. Conclusions: This report of long-term follow-up results of primary second-generation, all-inside meniscal repair demonstrates its relative success when it is performed with concurrent ACL reconstruction. After a minimum follow-up of 10 years, 84% to 88% of the patients continued to demonstrate successful repair. Failure of medial meniscal repairs occurred significantly earlier compared with lateral meniscal repairs. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Reference28 articles.

1. Arthroscopic repair of meniscus tears;Henning;Orthopedics.,1983

2. Arthroscopic meniscus repair with a posterior incision;Henning;Instr Course Lect.,1988

3. Long-term outcome after all inside meniscal repair using the FasT-Fix system;Zimmerer;J Orthop.,2018

4. Long-term outcome after all-inside meniscal repair using the RapidLoc system;Solheim;Knee Surg Sports Traumatol Arthrosc.,2016

5. Predictive factors for failure of meniscal repair: a retrospective dual-center analysis of 918 consecutive cases;Ronnblad;Orthop J Sports Med.,2020

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3