Comparing the Biomechanical Stability of Cerclage Cable with Plate Insert Versus Locking Screw in Periprosthetic Humeral Fracture

Author:

Lee Yong-Jun1ORCID,Lim Joon-Ryul1ORCID,Choi Jee-Hoon1ORCID,Yoon Tae-Hwan1ORCID,Choi Yun-Rak1ORCID,Chun Yong-Min1ORCID

Affiliation:

1. Arthroscopy and Joint Research Institute, Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea

Abstract

Background: In the setting of periprosthetic humeral fractures, the humeral stem of the implant represents a substantial challenge to the optimal method of proximal fixation. This study aimed to compare the initial biomechanical stability provided by cerclage cables with a locking plate insert versus bicortical locking screws (i.e., the gold standard for fixation) in fresh cadaveric humeri. Methods: After calculating the sample size, we utilized 10 sets of cadaveric specimens and created a 5-mm osteotomy gap 120 mm distal to the tip of the greater tuberosity, simulating a Wright and Cofield type-B periprosthetic humeral fracture on each specimen. Using 3 locking screws for distal fragment fixation, identical in all specimens, the specimens were assigned to Group A (3 cerclage cables with a plate insert) or Group B (3 locking bicortical screws) for proximal fragment fixation. Biomechanical tests included stiffness in varus and valgus bending, torsion, and axial compression, and a single load to failure. Results: No significant differences were observed in the biomechanical metrics between the 2 groups. Conclusions: Our study revealed that fixation with use of cerclage cables with a plate insert demonstrated biomechanical stability comparable with that of bicortical locking screw fixation when addressing the proximal fragment in Wright and Cofield type-B periprosthetic humeral fractures. Clinical Relevance: For proximal fragment fixation of periprosthetic humeral fractures, cerclage cables with a plate insert can be utilized as an effective fixation method that offers initial fixation strength that is comparable to the use of 3 locking bicortical screws.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference25 articles.

1. Shoulder replacement surgery for osteoarthritis and rotator cuff tear arthropathy;Craig;Cochrane Database Syst Rev.,2020

2. Increasing incidence of shoulder arthroplasty in the United States;Kim;J Bone Joint Surg Am.,2011

3. Management of periprosthetic fractures of the humerus: a systematic review;Mourkus;Bone Joint J.,2022

4. Complications of total shoulder arthroplasty;Bohsali;J Bone Joint Surg Am.,2006

5. Complications of total shoulder arthroplasty: are they fewer or different?;Chin;J Shoulder Elbow Surg.,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3