The Diagnostic Utility of Fast Tests for Detecting C-Reactive Protein in Synovial Fluid in Periprosthetic Joint Infections

Author:

Grzelecki Dariusz1ORCID,Grajek Aleksandra2ORCID,Otworowski Maciej3ORCID,Paskal Wiktor4ORCID,Fulin Petr5ORCID,Kowalczewski Jacek1ORCID

Affiliation:

1. Department of Orthopedics and Rheumoorthopedics, Centre of Postgraduate Medical Education, Prof. Adam Gruca Orthopedic and Trauma Teaching Hospital, Otwock, Poland

2. Central Laboratory, Prof. Adam Gruca Orthopedic and Trauma Teaching Hospital, Otwock, Poland

3. Department of Orthopaedic Surgery and Traumatology, Southern Hospital, Warsaw, Poland

4. Department of Methodology, Centre for Preclinical Research, Medical University of Warsaw, Warsaw, Poland

5. 1st Department of Orthopaedics, First Faculty of Medicine of Charles University and Motol University Hospital, Prague, Czech Republic

Abstract

Background: Despite the fact that many synovial fluid biomarkers have found application in the routine diagnosis of periprosthetic joint infection (PJI), this process still remains a challenge for orthopaedic surgeons. To simplify this process, fast point-of-care (POC) tests can be used during ambulatory visits and in operating room conditions. However, before such tests can be routinely used in clinical practice, they require validation. The purpose of the present study was to evaluate the diagnostic accuracy of different fast POC tests for detecting C-reactive protein (CRP) in synovial fluid for the diagnosis of PJI. Methods: Synovial fluid samples were collected from 120 consecutive patients who underwent revision total joint arthroplasty (TJA). The patients were divided into 2 groups. The first group included 76 patients who underwent revision for reasons other than infection (the aseptic revision TJA [arTJA] group), and the second group included 44 patients who underwent revision because of periprosthetic joint infection (PJI). The diagnosis of infection was made according to the International Consensus Meeting (ICM) 2018 criteria. All patients were operatively treated at a single orthopaedic center from January 2022 to February 2023. Four fast CRP tests with different cutoff values (1 and 3 mg/L, ≥8 mg/L, ≥10 mg/L [cassette], ≥10 mg/L [strip]) were used off-label for synovial fluid testing. Tests were performed on the same synovial fluid samples, and the results of these tests were compared with those obtained with the laboratory method. Results: The cassette test with a minimum cutoff value of ≥8 mg/L demonstrated the best accuracy for the diagnosis of chronic PJI, with a sensitivity and specificity of 90.9% and 90.8%, respectively. For the cassette test with a cutoff value of >3 mg/L, the sensitivity and specificity were 68.2% and 77.6%, respectively. For the tests with a minimum cutoff value of ≥10 mg/L, the sensitivity and specificity were 77.3% and 94.7%, respectively, for the cassette test and 77.3% and 96.1%, respectively, for the strip test. The laboratory method with the statistically calculated threshold (2.7 mg/L) revealed the highest AUC (area under the receiver operating characteristic curve) value (0.95), with 90.9% sensitivity and 94.7% specificity. Conclusions: The cassette POC test with the minimum cutoff value of ≥8 mg/L had very good accuracy for the diagnosis of chronic PJI. This test had comparable sensitivity and slightly lower specificity in comparison with the laboratory method with the calculated threshold of 2.7 mg/L. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3