3D-Printed Metaphyseal Cones in Revision Total Knee Arthroplasties

Author:

Carender Christopher N.1ORCID,Bothun Cole E.1,Taunton Michael J.1ORCID,Perry Kevin I.1ORCID,Bedard Nicholas A.1ORCID,Pagnano Mark W.1ORCID,Abdel Matthew P.1ORCID

Affiliation:

1. Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota

Abstract

Background: Porous metaphyseal cones are frequently utilized during revision total knee arthroplasty (TKA) procedures. The purpose of the present study was to evaluate 3D-printed metaphyseal cones used for revision TKA, with specific emphasis on implant survivorship, radiographic appearance, and clinical outcomes after short-term follow-up. Methods: We identified 740 cones (498 tibial, 242 femoral) that had been inserted during 533 revision TKA procedures that had been performed at a single tertiary care academic institution. Aseptic loosening (n = 199), periprosthetic joint infection (PJI) (n = 183), and instability (n = 84) were the most common reasons for the index revision. Type-2B or 3 bone loss was present in 67% of the knees. The mean age was 66 years, the mean body mass index was 34 kg/m2, and 55% of the patients were female. Serial radiographs were reviewed. The mean duration of follow-up was 4 years. Results: The 5-year cumulative incidence of cone revision for aseptic loosening was 1% (95% confidence interval [CI], 0% to 3%). The 5-year cumulative incidence of any cone revision or removal was 6% (95% CI, 4% to 9%). In total, 37 cones (19 femoral, 18 tibial) were revised, with PJI (n = 23; 14 recurrent), periprosthetic femoral fracture (n = 3), arthrofibrosis (n = 3), and aseptic loosening of the femoral component and femoral cone (n = 3) as the most common reasons for cone revision. The 5-year cumulative incidence of any TKA re-revision was 14% (95% CI, 11% to 18%). There were a total of 67 re-revisions, with PJI (n = 38), persistent drainage (n = 6), and extensor mechanism disruption (n = 3) being the most common reasons. Radiographically, 2 unrevised femoral cones and 1 unrevised tibial cone appeared to be possibly loose; all 3 cones were in knees with distal femoral replacements or hinged constructs. Conclusions: This large series showed that 3D-printed titanium metaphyseal cones were very durable at short-term follow-up, with a 5-year cumulative incidence of cone revision for aseptic loosening of 1%. PJI was the most common reason for cone revision and any revision. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3