Effect of Different Iterative Reconstruction Algorithms on Ultra-Low Dose CT of Inflammatory Bowel Disease in a Rabbit Model

Author:

Shin Cheong-IlORCID,Kim Se HyungORCID,Yu Mi HyeORCID,Joo IjinORCID,Han Joon KooORCID

Abstract

Purpose: To evaluate the feasibility of ultra-low dose 80 kVp CT for the evaluation of inflammatory bowel disease (IBD) in a rabbit model and to investigate the effect of two different iterative reconstruction (IR) algorithms on 80 kVp CT in terms of image quality and diagnostic performance in comparison with same session conventional 120 kVp images.Materials and Methods: This study was approved by the Animal Care and Use Committee of our hospital. Twenty-eight New Zealand white rabbits were randomly divided into two groups: IBD group (n=18) and a control group (n=10). To create an acute IBD model, 3mL of a 5% w/v tri-nitrobenzene sulfonic acid solution was administered to the sigmoid colon of the rabbits. CT was performed at 80 kVp and 120 kVp and was reconstructed using filtered back projection (FBP), hybrid statistic-based IR, and full IR algorithms for 80 kVp and using FBP only for 120 kVp. Effective radiation dose, image noise, image quality, and diagnostic performance by two reviewers were recorded and compared using repeated measure analysis of variance, McNemar test, and receiver operating curve (ROC) analysis.Results: Mean effective radiation dose of 80 kVp CT (0.05 mSv) was significantly lower than that (0.285 mSv) of 120 kVp CT. Mean image noise was highest in the 80 kVp FBP setting (60.36) but significantly decreased with IR algorithms (47.02 with hybrid IR and 12.92 with full IR) (P<0.0001). Mean overall image quality score was lowest in the 80 kVp FBP setting (1.57 and 1.46 for reviewers 1 and 2, respectively) but significantly improved with IR algorithms (2.43 and 2.25 for hybrid IR and 4.79 and 4.93 for full IR) (P<0.0001). Sensitivity and area under the curve (AUC) for differentiating a normal bowel from IBD was lowest with 80 kVp FBP (61.1% and 83.3%; 0.883 and 0.967) but improved with IR algorithms (83.3%~100%; 0.992~1), to similar levels as the 120 kVp FBP setting (100% and 1). Differences in sensitivity and AUC between 80 kVp FBP and 80 kVp IR algorithms were statistically significant in reviewer 1.Conclusions: Ultra-low dose 80 kVp CT in a rabbit IBD model is not feasible using the standard FBP algorithm. However, with the application of IR algorithms, diagnostic performance of 80 kVp CT was acceptable and on par with that at conventional 120 kVp FBP.

Funder

National Research Foundation of Korea

Ministry of Science, ICT and Future Planning

Publisher

The Korean Society of Abdominal Radiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3