Author:
Wang Wei,Yu Yuanmeng,Wen Jiqiu,Zhang Mingchao,Chen Jinsong,Cheng Dongrui,Zhang Longjiang,Liu Zhihong
Abstract
Background and objectivesRecent developments indicated that functional magnetic resonance imaging (MRI) could potentially provide noninvasive assessment of kidney interstitial fibrosis in patients with kidney diseases, but direct evidence from histopathology is scarce. We aimed to explore the diagnostic utilities of functional MRI for the evaluation of kidney allograft interstitial fibrosis.Design, setting, participants, & measurementsWe prospectively examined 103 kidney transplant recipients who underwent for-cause biopsies and 20 biopsy-proven normal subjects with functional MRI. Histomorphometric analyses of interstitial fibrosis and peritubular capillary densities were performed on digitally scanned Masson’s trichrome- and CD34-stained slides, respectively. The performances of functional MRI to discriminate interstitial fibrosis were assessed by calculating the area under the curve using receiver-operating characteristic curve.ResultsMain pathologic findings in this single-center cohort were representative of common diagnostic entities in the kidney allografts, with rejection (32%) and glomerulonephritides (31%) accounting for the majority of diagnoses. Apparent diffusion coefficient from diffusion-weighted imaging correlated with interstitial fibrosis (ρ=−0.77; P<0.001). Additionally, decreased arterial spin labelings were accompanied by peritubular capillary density reductions (r=0.77; P<0.001). Blood oxygen level–dependent (BOLD) imaging demonstrated cortical hypoxia with increasing interstitial fibrosis (ρ=0.61; P<0.001). The area under the curve for the discrimination of ≤25% versus >25% interstitial fibrosis and ≤50% versus >50% interstitial fibrosis were 0.87 (95% confidence interval [95% CI], 0.79 to 0.93) and 0.88 (95% CI, 0.80 to 0.93) by apparent diffusion coefficient, 0.92 (95% CI, 0.85 to 0.97) and 0.94 (95% CI, 0.87 to 0.98) by arterial spin labeling, 0.81 (95% CI, 0.72 to 0.88) and 0.86 (95% CI, 0.78 to 0.92) by perfusion fraction, 0.79 (95% CI, 0.69 to 0.87) and 0.85 (95% CI, 0.76 to 0.92) by BOLD imaging, respectively.ConclusionsFunctional MRI measurements were strongly correlated with kidney allograft interstitial fibrosis. The performances of functional MRI for discriminating ≤50% versus >50% interstitial fibrosis were good to excellent.
Funder
National Key Research and Development Program of China
Natural Scientific Foundation of China
Publisher
American Society of Nephrology (ASN)
Subject
Transplantation,Nephrology,Critical Care and Intensive Care Medicine,Epidemiology
Cited by
50 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献