Affiliation:
1. Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
2. Formerly Eidgenössische Technische Hochschule Zürich (ETHZ), 8093 Zürich, Switzerland
3. EUCENTRE, 27100 Pavia, Italy
Abstract
This paper presents the results of an experimental campaign on masonry spandrels. Within this campaign, four masonry spandrels were subjected to quasi-static cyclic loading. Two different spandrel configurations were tested. The first configuration comprised a masonry spandrel with a timber lintel, and the second configuration, a masonry spandrel on a shallow masonry arch. For each configuration, two specimens were tested. The first was tested with a constant axial load in the spandrel, while for the second specimen, the axial load in the spandrel depended on the axial elongation of the spandrel. This paper summarizes the properties of the four test units, the test setup, and the most important results from the experiments, documenting the failure mechanisms that developed and the force-deformation hysteresis of the spandrel elements. The paper also presents a mechanical model for estimating the peak strength of masonry spandrels.
Subject
Geophysics,Geotechnical Engineering and Engineering Geology
Cited by
87 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献