Author:
Shang Fu-Min,Liu Deng-Ying,Xian Hai-Zhen,Liu Jian-Hong,Chen Guo-Hua
Abstract
Experiments were performed on a closed loop self-exciting mode oscillating flow heat pipe (SEMOS HP) with uniform and non-uniform structures under the same tested conditions. The heat transfer characteristics are analyzed by comparing the temperature of wall of the heat pipe and output power when the heat input of the electric heating board and heating position are changed. The result shows that the heat transfer rate could be improved by using a non-uniform structure under low or middle heat input, and it gives the highest heat transfer performance when the non-uniform diameter section is at the bottom of the heat pipe and the heating source located below the non-uniform section.
Subject
Engineering (miscellaneous),Food Science,Biotechnology
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献