Application of Radial Acquisition Multishot sequence in Multiparametric MRI of prostate

Author:

Curatolo Calogero1ORCID,Pizzolato Mariangela2,Daricello Marco3,Caruso Virginia3,Lo Re Giuseppe4ORCID,Salvaggio Giuseppe2ORCID,Galia Massimo2ORCID

Affiliation:

1. Dipartimento di Diagnostica per immagini, A.O.U.P. "P. Giaccone", Palermo

2. Sezione di Scienze radiologiche, BIND, Università degli Studi di Palermo

3. Dipartment of Radiology, A.O.U.P. "P. Giaccone", Palermo

4. Radiology Section, BIND, University of Palermo

Abstract

The purpose of our study is to evaluate the T2 weighted sequence with multishot radial sampling (Radial Acquisition Multi-shot) also known as Multivane sequence in Philips Healthcare, introduced by J.Pipe with the aim to minimize motion artifacts in Magnetic Resonance Imaging (MRI). In the field of prostate MRI the Multivane sequence is useful in non-cooperating patients and/or patients who, due to their clinical conditions (such as glaucoma, arrhythmia, and severe benign prostatic hypertrophy), have not been receiving intravenous antispasmodic agents, administered for limiting the motility of intestinal loops, particularly rectum. The Multivane sequence is based on the collection of data throughout parallel multiple lines in periodic rotation around the center of k-space and advanced mathematical reconstruction. As the data at the center of k-space (low frequency) containing signals with maximum amplitude will be continuously sampled, this trajectory will provide an excellent contrast-noise ratio (CNR) and spatial resolution, without motion artifacts responsible of "blurring" in the final image. Specifically, each given point of the periphery of the k-space will be sampled by a certain line and the next one and so on, and for the final image reconstruction, once multiple data will be estimated, different algorithms will be used to compensate for motion artifacts. In this study we compared the Radial Acquisition Multishot TSE Multivane (Philips Healthcare) with the classic T2W TSE sequences with linear Cartesian sampling. Multivane sequences have proven to be superior and therefore of greater utility compared to sequences with linear Cartesian data sampling, in patients who can not receiving spasmolytic agents.

Publisher

Ordine TSRM PSTRP di Napoli, Avellino, Benevento

Subject

Earth-Surface Processes

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3