CTMS in the study of post-EVAR endoleak in the treatment of aneurysmal dilations

Author:

Marco Coda1ORCID,Anna Novak2,Daniele Aliberti3,Vincenzo Ciccone4,Mattia Carbone5

Affiliation:

1. Dott. TSRM - A.O.U. “San Giovanni di Dio e Ruggi d’Aragona Salerno"

2. Dott.ssa TSRM– “Università degli studi di Salerno”

3. Dott. TSRM - A.O.U. “San Giovanni di Dio e Ruggi d’Aragona Salerno”

4. Dirigente Medico Dott. - A.O.U. “San Giovanni di Dio e Ruggi d’Aragona Salerno” U.O. Radiologia

5. Dirigente Medico Dott. - A.O.U. “San Giovanni di Dio e Ruggi d’Aragona Salerno” U.O. Radiologia, Direttore f.f. U.O. Radiologia

Abstract

Computed tomography angiography (CTA) has been widely used in diagnostic evaluation of many aortic diseases, but there are not standardized techniques for aortic CTA. The purpose of this study is to compare two methods: biphasic technique and split bolus. A 64-slice CT scanner has been used. There were a total of 28 patients involved in the study. The patients have been divided in two groups: - Group A: 18 patients - Group B: 10 patients The biphasic technique has been used on 18 patients in group A. In this protocol was used a low dose acquisition without contrast medium (CM) and two contrastographic phases with CM. The split bolus technique was performed on 10 patients of group B. 120-140 ml of CM are divided in two boluses. The first bolus of 55-90 ml of CM was injected at a flow of 1,5-2 ml/s, followed by 20ml of physiological solution at a flow of 1,5-2ml/s. After physiological solution the second bolus of 35-60 ml was injected at a flow of 3,5ml/s followed by 20ml of Nacl at a flow of 3,5ml/s. In group A 6 patients had endoleak type I, n=2 endoleak type II, n=8 endoleak type III, n=2 endoleak type IV. (dose of 43.2 mSv). In group B 2 patients had endoleak type I, n= 4 endoleak type II, n=3 endoleak type III and n=1 endoleak type IV. (dose of 16,39 mSv). The biphasic technique has high spatial resolution and contrast resolution, reduction of acquisition times and reduction of artifacts, but an unacceptable a great amount of radiation is involved. The split bolus technique provides results comparable to the biphasic technique but with a lower dose of radiation.

Publisher

Ordine TSRM PSTRP di Napoli, Avellino, Benevento

Subject

Earth-Surface Processes

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3