Step-up/step-down regulators in maximum power transmission mode

Author:

Romashko V. Y.ORCID,Batrak L. M.ORCID,Abakumova O. O.ORCID

Abstract

Introduction. Switching DC voltage regulators are traditionally used to regulate and stabilize the voltage on the load. Due to the widespread use of non-traditional and renewable sources of electricity, there is a need to select from them the maximum possible amount of electricity. As is known, the maximum power from the power supply to the load will be transmitted provided that the output resistance of the source is equal to the load resistance. If this condition is not met, a matching switching regulator is switched on between the power supply and the load. Most often, for the purpose of matching, pulse regulators of step-up or step-down types are used. Problem. The operation of regulators in the matching mode has a number of features, in comparison with the modes of regulation and stabilization of the output voltage. Thus, since in the maximum power transmission mode the output resistance of the source and the resistance of the load are values of the same order, in any calculation the internal resistance of the source must be taken into account. There are works in which features of work of regulators of step-up and step-down types in a mode of transfer of the maximum power are analyzed. In addition to these types of pulse regulators, there are regulators of step-up/step-down types, which are relatively rarely used for this purpose. First of all it is connected with insufficiently studied abilities of work of such regulators in the specified mode. Goal. The aim of the work is to analyze the features of the operation of pulse regulators of step-up/step-down types in the mode of transmission of maximum power from the power supply to the load, as well as to determine the conditions under which it is possible and appropriate to work in this mode. Methodology. In the work, taking into account the internal resistance of the power supply, the regulation characteristics of the basic circuit of the pulse regulator of the step-up/step-down type are analyzed. The conditions under which the transfer of maximum power from the power supply to the load is ensured are determined. Results. It is shown that the existing variants of the circuits of regulators of the step-up/step-down type can be obtained from the basic circuit by applying the rules of construction of dual electric circuits. Consequently, the basic calculated relations for such circuits can be obtained from the calculated relations of the basic circuit using the principle of duality. Originality. A method for determining and studying the regulation characteristics of pulse regulators, taking into account the internal resistance of the power supply. Practical value. The obtained results allow to determine the conditions under which it is possible and expedient to operate different circuits of regulators in the mode of transmission of maximum power from the power supply to the load. Based on these results, recommendations are given for selecting a suitable range for changing the relative time of the closed state of the controlled switch, depending on the type of power supply used, as well as the method of connecting the controlled switch in the regulator circuit.

Publisher

National Technical University Kharkiv Polytechnic Institute

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3