The method for design of combined electromagnetic shield for overhead power lines magnetic field

Author:

Kuznetsov B. I.ORCID,Nikitina T. B.ORCID,Bovdui I. V.ORCID,Chunikhin K. V.ORCID,Kolomiets V. V.ORCID,Kobylianskyi B. B.ORCID

Abstract

Aim. Development of the method of designing a combined electromagnetic shield, consisting of active and passive parts, to improve the effectiveness of reduction of industrial frequency magnetic field created by two-circuit overhead power lines in residential buildings. Methodology. The problem of design of combined electromagnetic shield including robust system of active shielding and electromagnetic passive shield of initial magnetic field solved based on of the multi-criteria two-player antagonistic game. The game payoff vector calculated based on the finite element calculations system COMSOL Muliphysics. The game solution calculated based on the particles multiswarm optimization algorithms. During the design of combined electromagnetic shields spatial location coordinates of shielding winding, the currents and phases in the shielding winding of active shielding, geometric dimensions and thickness of the electromagnetic passive shield are calculated. Results. The results of theoretical and experimental studies of combined electromagnetic passive and active shielding of magnetic field in residential building from power transmission line with a «Barrel» type arrangement of wires presented. Originality. For the first time the method of designing a combined electromagnetic shield, consisting of active and passive parts, for more effective reduction of the magnetic field of industrial frequency created by two-circuit overhead power lines in residential buildings is developed. Practical value. Based on results of calculated and experimental study the shielding efficiency of the initial magnetic field determined that shielding factors whith only electromagnetic passive shield is more 2 units, whith only active shield is more 4 units and with combined electromagnetic passive and active shield is more 10 units. It is shown the possibility to reduce the level of magnetic field induction in residential building from power transmission line with a «Barrel» type arrangement of wires by means of a combined electromagnetic passive and active shielding with single compensating winding to 0.5 μT level safe for the population. References 53, figures 15.

Publisher

National Technical University Kharkiv Polytechnic Institute

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3