Preoperative aortic annulus size assessment by transthoracic echocardiography compared to the size of surgically implanted aortic prostheses

Author:

Ingimarsdóttir I J1,Hellgren Johansson L2,Flachskampf F A3

Affiliation:

1. 1Department of CardiologyUppsala University Hospital, Uppsala, Sweden

2. 2Department of Cardiothoracic SurgeryUppsala University Hospital, Uppsala, Sweden

3. 3Department of Medical SciencesClinical Physiology, Uppsala University and Uppsala University Hospital, Uppsala, Sweden

Abstract

Objectives The aortic annulus diameter measured by transthoracic echocardiography yields lower values than by computed tomography, and echo-based selection of transcatheter aortic valve prosthesis size has been implied to result in more frequent paravalvular leakage. We investigated the relation of preoperative annulus diameter by echo with the ring size of the aortic prosthesis chosen by direct assessment during open-heart aortic valve replacement. Methods Preoperative annulus diameter by echo (from parasternal long-axis cross-sections of the left ventricular outflow tract and aortic valve) and implanted prosthetic diameter (tissue annulus diameter, determined intraoperatively using a sizing instrument) were compared retrospectively in 285 consecutive patients undergoing open-heart aortic valve replacement. Results A total of 285 prostheses (240 biologic and 45 mechanical) were implanted, with prosthetic diameter ranging between 19 and 27 mm. There was a significant linear correlation (P < 0.0001) with r = 0.51, between preoperative annulus diameter by echo (mean 21.8 ± 2.8 mm) and prosthetic diameter (22.9 ± 1.7 mm). Preoperative annulus diameter of patients receiving prostheses no. 21, 23 and 25 mm aortic prostheses (the most frequent prosthesis sizes) were significantly different (P < 0.001) from each other. On average, preoperative annulus diameter by echo underestimated prosthetic diameter by a bias of 1.07 mm. Conclusion Our data confirm that preoperative echo assessment of the aortic valve may slightly underestimates the optimal surgical prosthesis diameter for the aortic valve annulus.

Publisher

Springer Science and Business Media LLC

Subject

Advanced and Specialized Nursing,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3