Two-dimensional global and segmental longitudinal strain: are the results from software in different high-end ultrasound systems comparable?

Author:

Patrianakos Alexandros P,Zacharaki Aggeliki A,Kalogerakis Antonios,Solidakis Georgios,Parthenakis Fragiskos I,Vardas Panos E

Abstract

To compare the peak global longitudinal myocardial strain (PGLS) and peak segmental longitudinal myocardial strain (PSLS) values by speckle-tracking echocardiography (STE) obtained using two different echocardiography devices. STE is an emerging quantitative ultrasound technique that allows an accurate evaluation of global and segmental myocardial function. However, there is a lack of standardization of the acquired data among different manufacturers. Sixty-three subjects, mean age 56.2±10.4 years, underwent complete echocardiographic studies with two different devices (Philips IE33 and General Electric VIVID E9) performed by the same operator. Thirty-one of them had known cardiac disease, with estimated left ventricular ejection fraction <50%, while 32 were free of any cardiovascular disease (control subjects). All images were digitally stored and analyzed using off-line post processing with QLAB 9 and EchoPAC 11 Software packages. PSLS and PGLS were calculated. A strong relationship between QLAB and EchoPAC was found for PGLS (r=0.91, P<0.001), PSLS-4 chamber (CH; r=0.79, P<0.001), PSLS-2CH (r=0.73, P<0.001), and PSLS-3CH (r=0.78, P<0.001) QLAB. Bland–Altman analysis showed absolute differences vs average of −0.16, −0.37, −0.21, and −0.16 for PGLS, PSLS-4CH, PSLS-2CH, and PSLS-apical long-axis views respectively. Segmental analysis showed a good agreement between the apical segments, whereas poor correlations were found for the basal segments. Receiver operating characteristic curve analysis showed that cutoff values for PGLS of −17.5 and −17.75% with Philips or GE systems gave a sensitivity and specificity of 93.5 and 87.5%, and 90 and 87.5%, respectively, in the discrimination of the patients from the controls. Both Philips and GE echo stations were found to give comparable results for PGLS, with approximately the same cutoff values, suggesting that their PGLS results may be interchangeable.

Publisher

Springer Science and Business Media LLC

Subject

Advanced and Specialized Nursing,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3