A new generation IRMA for ACTH with improved specificity: validation in various physiological and pathological conditions

Author:

Guiban D,Massias JF,Dugue MA,Coste J,Bertagna X,Raffin-Sanson ML

Abstract

OBJECTIVE: Measurement of plasma ACTH is a key step for the exploration of hypothalamic-pituitary-adrenal disorders. To further improve ACTH recognition a new generation of ACTH IRMA was developed using antibodies directed towards succinylated ACTH (sACTH IRMA). DESIGN: The usefulness of this assay was compared with that of another commercially available ACTH IRMA assay using intact ACTH (ELSA-ACTH) in various pathophysiological situations: patients with low ACTH plasma levels, high ACTH plasma levels with normal or tumoural pituitaries, or ectopic ACTH syndrome, and pregnant women with high proopiomelanocortin (POMC) plasma levels. METHODS: All plasma samples were assayed simultaneously with the two different IRMAs. Comparisons were assessed by plotting the results along the theoretical line of identical values, and by the graphical method of Bland and Altman. RESULTS: In the ELSA-ACTH IRMA, CLIP (or ACTH18-39) showed true cross-reactivity, and alpha-melanocyte-stimulating hormone and purified POMC both interfered and induced falsely lower ACTH results; in the sACTH IRMA no peptide showed any cross-reactivity, and only extremely high values of CLIP (50 000 pg/ml) interfered and induced falsely lower ACTH results. In ACTH hypersecretory syndromes, of tumoural (Cushing's disease, ectopic ACTH secretion) or non-tumoural (Addison's disease, congenital adrenal hyperplasia) origins a good agreement between the two assays was observed except for very high ACTH plasma values (above 1000 pg/ml) and in some tumours where the sACTH IRMA yielded lower results; in some cases, the presence of circulating CLIP, demonstrated by HPLC studies, may contribute to this discrepancy. It is also likely that the calibration of the ELSA-ACTH kit itself generates higher ACTH values. In normal pregnant women both IRMAs gave highly correlated values, yet lower results were obtained with the sACTH IRMA. CONCLUSION: These data show that the sACTH IRMA has improved qualities of specificity and usefulness for rapid assessment of ACTH plasma levels.

Publisher

Bioscientifica

Subject

Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3