Toward a consensus on reference values for thyroid volume in iodine-replete schoolchildren: results of a workshop on inter-observer and inter-equipment variation in sonographic measurement of thyroid volume

Author:

Zimmermann MB,Molinari L,Spehl M,Weidinger-Toth J,Podoba J,Hess S,Delange F

Abstract

OBJECTIVE: Interpretation of thyroid ultrasonography for assessing goiter prevalence requires valid reference criteria from iodine-sufficient populations. Reports have suggested the current reference criteria for thyroid volume (T(vol)) of WHO/ICCIDD (International Council for the Control of Iodine Deficiency Disorders) may be too high. Our objective was to determine if inter-observer and/or inter-equipment variability contributes to the disagreement in sonographic T(vol) in children reported from iodine-sufficient areas. DESIGN: A 2-day workshop in which four experienced ultrasound examiners from around Europe measured T(vol) in 45 6--12-year-old Swiss schoolchildren using four different portable ultrasound machines. One of the participating examiners (observer A) had generated the T(vol) data in European children that are the basis for the WHO/ICCIDD reference criteria. METHODS: Sonographic T(vol) was measured in each child by all four examiners on all four machines. Six hundred and eighty-four examinations were completed, with examiners having no knowledge of one another's results. Inter-observer and inter-equipment variation was calculated. RESULTS: Mean inter-equipment variation in T(vol) was 15.2% (95% CI: 14.1, 16.3%). There were no significant differences in T(vol) between equipment (P=0.51). For all observers, the mean inter-observer variation in T(vol) was 25.6% (95% CI: 23.9, 27.2%). At all ages and all body surface areas, there was a large systematic measurement bias (+30% volume) between the mean T(vol) of observer A and the mean Tvol of observers B, C and D. Reanalysis using data from observers B, C and D reduced the mean inter-observer variation in T(vol) to 13.3% (95% CI: 11.9, 14.7%). A correction factor for the systematic difference of operator A for the P50 and P97 of T(vol) was estimated using analysis of covariance. When applied to the WHO/ICCIDD reference data, it sharply reduced the discrepancy between the WHO/ICCIDD criteria and those from other iodine-sufficient children around the world. CONCLUSIONS: Inter-equipment error contributes minimally to reported differences in sonographic T(vol). Even among experienced examiners, inter-observer variation in sonographic T(vol) in children can be high, and probably contributes to the current disagreement on normative values in iodine-sufficient children. A systematic bias at least partially explains why the WHO/ICCIDD reference data differ from those reported from other iodine-sufficient children around the world. The findings argue strongly for the standardization of methods used for sonographic measurement of T(vol) in children.

Publisher

Bioscientifica

Subject

Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3