BIOLOGICALLY ACTIVE LUTEINIZING HORMONE (LH) IN PLASMA

Author:

Romaní P.,Robertson D. M.,Diczfalusy E.

Abstract

ABSTRACT A recently described in vitro bioassay method for the measurement of biologically active LH (Van Damme et al. 1974) has been applied to the plasma of normally menstruating and post-menopausal women. The specificity of the procedure was established according to the following evidence: 1. Parallelism was observed between dose response curves obtained with serial dilutions of a standard LH preparation (HMG 2nd IRP) and plasma pools collected during the follicular phase, at the LH-peak, during the luteal phase and after menopause. 2. There was no evidence for the presence of any synergistic or antagonistic factor in the various plasma specimens. The assay design used to establish this consisted of assaying the standard and plasma pool separately and then together as a mixture followed by an asssessment of the difference (if any) in the potencies obtained. Strict additivity should yield a relative potency of 1.0. Plasma pools which were obtained every 2–3 days throughout the menstrual cycle were assayed using this design against the standard (HMG 2nd IRP) and against a mid-cycle plasma pool obtained at the time of the LH-peak. The latter was also assayed against partially purified plasma fractions obtained from a post-menopausal plasma pool after gel filtration and isoelectric focusing. With the exception of 3 assays, in which the estimates of relative potency were 0.91, 0.94 and 0.95, respectively, in 19 assays of additivity, the fiducial limits always included unity. 3. Non-detectable LH levels were found in the plasma or serum of either hypophysectomized or hypopituitary hypogonadal men or women treated with oestrogen/progestogen combined pills. 4. The presence of calf or human serum in the assay medium is an essential requirement for a valid comparison of standard and unknown preparations. In their absence, non-parallel dose response curves between plasma and standard were obtained. The other established criteria of reliability (sensitivity and precision) were also examined. The method is sufficiently sensitive (3.5–8.0 mIU/ml plasma; HMG (2nd IRP) as standard) for the measurement of LH throughout the cycle. The mean index of precision (λ) in 230 multiple assays was 0.040. It is concluded that the modified bioassay yields valid and reliable estimates of LH when applied to human plasma obtained throughout the menstrual cycle and after menopause.

Publisher

Bioscientifica

Subject

Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3