Affiliation:
1. Clinical Chemistry DivisionDepartment of Laboratory Medicine, National Institutes of Health, Bethesda, Maryland, USA
Abstract
Hypothyroidism is a very common disorder worldwide, for which the usual treatment is monotherapy with levothyroxine (L-T4). However, a number of patients treated with L-T4 continue to report symptoms of hypothyroidism despite seemingly normal levels of thyroid-stimulating hormone (TSH), free-T3 (FT3) and free-T4 (FT4) measured by immunoassay. This review summarizes the limitations of the immunoassays commonly used to measure thyroid hormone levels and emphasizes the advantages of the role of liquid chromatography-tandem mass spectrometry (LC-MS/MS). Immunoassays for free thyroid hormone are affected by alterations in serum binding proteins that occur in many physiological and disease states. Multiple studies show falsely normal values for T3, FT3 and FT4 by immunoassay that are below the reference interval when measured by (ultrafiltration) LC-MS/MS, a reference method. We suggest evaluation of thyroid hormone levels by ultrafiltration LC-MS/MS for patients who continue to experience hypothyroid symptoms on LT-4. This may help identify the approximately 20% subset of patients who would benefit from addition of T3 to their treatment regimen (combination therapy).
Subject
Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism
Cited by
86 articles.
订阅此论文施引文献