Affiliation:
1. 1South West London Elective Orthopaedic Centre, Epsom General Hospital, Epsom, Surrey, UK
Abstract
There are advocates of both two-dimensional (2D) and three-dimensional (3D) templating methods for planning total hip replacement.
The aim of this study was to compare the accuracy of implant size prediction when using 2D and 3D templating methods for total hip arthroplasty, as well as to compare the inter- and intra-observer reliability in order to determine whether currently available methods are sufficiently reliable and reproducible.
Medline, EMBASE and PubMed were searched to identify studies that compared the accuracy of 2D and 3D templating for total hip replacement.
Results were screened using the PRISMA flowchart and included studies were assessed for their level of evidence using the Oxford CEBM criteria. Non-randomized trials were critically appraised using the MINORS tool, whilst randomized trials were assessed using the CASP RCT checklist.
A series of meta-analyses of the data for accuracy were also conducted.
Ten studies reported that 3D templating is an accurate and reliable method of templating for total hip replacement. Six studies compared 3D templating with 2D templating, all of which concluded that 3D templating was more accurate, with three finding a statistically significant difference.
The meta-analyses showed that 3D CT templating is the most accurate method.
This review supports the hypothesis that 3D templating is an accurate and reliable method of preoperative planning, which is more accurate than 2D templating for predicting implant size. However, further research is needed to ascertain the significance of this improved accuracy and whether it will yield any clinical benefit.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
22 articles.
订阅此论文施引文献