Serum thyroglobulin evaluation on LC-MS/MS and immunoassay in TgAb-positive patients with papillary thyroid carcinoma

Author:

Nishihara Eijun1,Hobo Yoshitaka2,Miyauchi Akira1,Ito Yasuhiro1,Higuchi Miyoko1,Hirokawa Mitsuyoshi1,Ito Mitsuru1,Fukata Shuji1,Nishikawa Mitsushige1,Akamizu Takashi1

Affiliation:

1. 1Kuma Hospital, Center for Excellence in Thyroid Care, Kobe, Japan

2. 2ASKA Pharmamedical Co., Ltd. Fujisawa, Japan

Abstract

Objective This study aimed to elucidate disproportionately low serum thyroglobulin (Tg) values in Tg antibody (TgAb)-positive patients with structural recurrence of papillary thyroid carcinoma (PTC) using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Design A retrospective study was performed on 176 patients in whom Tg and TgAb levels were measured between 2016 and 2021. Several comprehensive analyses of Tg-LC-MS/MS with an electrochemiluminescence immunoassay for Tg (Tg-ECLIA) were conducted using serum samples. Methods TgAb-positive patients who underwent total thyroidectomy with multiple lung metastases due to PTC were evaluated using Tg-LC-MS/MS and Tg-ECLIA. Tg expression in lymph node metastases and metastatic lesions was evaluated by immunohistochemistry and Tg levels of aspiration washouts were also evaluated. Two in vitro assays were performed to elucidate TgAb interference. Results Tg concentrations of negative TgAb in both assays were similar (R2= 0.99; n  = 52). Patients with structural recurrence showed higher Tg values with Tg-LC-MS/MS than with Tg-ECLIA. The undetectable proportion was significantly lower with Tg-LC-MS/MS (31.6%, 6/19) than with Tg-ECLIA (68.4%, 13/19; P  = 0.023). The spike-recovery rate and Tg concentrations determined by the serum mixture text (n  = 29) were significantly reduced to 75.0% (118.3–88.7%) and 81.3% (107.0–87.0%), respectively, with TgAb using Tg-ECLIA (both P  < 0.001) confirming assay interference but not using Tg-LC-MS/MS (91.8–92.3%, P  = 0.77 and 98.4–100.8%, P  = 0.18, respectively). Conclusions TgAb had no effect on the Tg-LC-MS/MS assay but yielded 19–25% lower values in Tg-ECLIA. Tg-LC-MS/MS is preferable for monitoring serum Tg levels in TgAb-positive patients, although those with structural recurrence often had disproportionally low Tg values.

Publisher

Bioscientifica

Subject

Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3