How low can we (reliably) go? A method comparison of thyroid-stimulating hormone assays with a focus on low concentrations

Author:

Ursem Stan R12ORCID,Boelen Anita123ORCID,Hillebrand Jacquelien J12ORCID,den Elzen Wendy P J45ORCID,Heijboer Annemieke C1236ORCID

Affiliation:

1. Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC Location University of Amsterdam, Meibergdreef, Amsterdam, The Netherlands

2. Amsterdam Gastroenterology, Endocrinology & Metabolism, Amsterdam, The Netherlands

3. Amsterdam Reproduction & Development, Amsterdam, The Netherlands

4. Department of Laboratory Medicine, Laboratory Specialized Diagnostics & Research, Amsterdam UMC location University of Amsterdam, Meibergdreef, Amsterdam, The Netherlands

5. Amsterdam Public Health, Amsterdam, The Netherlands

6. Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC Location Vrije Universiteit Amsterdam, Boelelaan, Amsterdam, The Netherlands

Abstract

Objective International guidelines concerning subclinical hyperthyroidism and thyroid cancer advice absolute cut-off values for aiding clinical decisions in the low range of thyroid-stimulating hormone (TSH) concentrations. As TSH assays are known to be poorly standardized in the normal to high range, we performed a TSH assay method comparison focusing on the low range. Methods Sixty samples, selected to cover a wide range of TSH concentrations (<0.01 to 120 mIU/L) with oversampling in the lower range (<0.4 mIU/L), were used for the method comparison between three TSH immunoassays (Cobas, Alinity and Atellica). In addition, 20 samples were used to assess the coefficient of variation from duplicate measurements in these three methods. Results The TSH immunoassays showed standardization differences with a bias of 7–16% for the total range and 1–14% for the low range. This could lead to a different classification of 1.5% of all measured TSH concentrations <0.40 mIU/L measured in our laboratory over the last 6 months, regarding the clinically important cut-off value of TSH = 0.1 mIU/L. As the imprecision of the immunoassays varied from 1.6–5.5%, this could lead to a similar reclassification as the bias between immunoassays. Conclusions We established the standardization differences of frequently used TSH assays for the total and low concentration ranges. Based on the proportional bias and the imprecision, this effect seems to have limited clinical consequences for the low TSH concentration range. Nevertheless, as guidelines mention absolute TSH values to guide clinical decision-making, caution must be applied when interpreting values close to these cut-offs.

Publisher

Bioscientifica

Subject

Endocrinology, Diabetes and Metabolism

Reference17 articles.

1. Report of the IFCC working group for standardization of thyroid function tests; part 1: thyroid-stimulating hormone;Thienpont,2010

2. A progress report of the IFCC committee for standardization of thyroid function tests;Thienpont,2014

3. Harmonization of serum thyroid-stimulating hormone measurements paves the way for the adoption of a more uniform reference interval;Thienpont,2017

4. Implementing reference systems for thyroid function tests – a collaborative effort;Vesper,2021

5. Clinical concordance assessment should be an integral component of laboratory method comparison studies: a regression transference of routine clinical data approach;Kalaria,2022

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3