Abstract
Eddy current (EC) technology is commonly used for detecting flaws, measuring geometric parameters, or determining properties of conducting materials. However, the measurement of a particular parameter can become more challenging if multiple influential parameters vary simultaneously. In particular, eddy current-based measurement of separation (gap) between a pressure tube (PT) and a calandria tube (CT) in the fuel channels of CANDU® reactors is made more difficult by variations in PT wall thickness, resistivity, and probe lift-off. An analytical model of the EC response to changes in PT–CT gap has been developed by approximating the geometry of the PT within the larger diameter CT as a pair of concentric tubes, where gap is varied by changing the CT radius. In this article, this model is used in combination with an error minimization algorithm to construct an inverse algorithm for the extraction of PT–CT gap, PT resistivity (ρ), and PT wall thickness (WT) from measured multi-frequency eddy current signals. Application of a linear regression tool in MATLAB, with fourth-order polynomial fitting of modeled data with varying ρ and WT as a function of PT–CT gap, is used to obtain coefficients that depend on ρ and WT. Output of multidimensional fitting of these coefficients is scaled and rotated to calibration data. Finally, implementation of an error minimization algorithm in MATLAB is used to produce estimates of multiple target parameters from experimental data. Simultaneous extraction of either one, two, or three parameters is examined, using experimental data obtained at frequencies used for in-reactor inspection of 4.2, 8, and 16 kHz, or just two frequencies of 4.2 and 8 kHz. Under full gap variation conditions, the inverse algorithm predicts gap to within 0.1 mm at gaps between 0 and 9 mm and to within 0.4 mm at gaps between 9 and 18 mm. PT resistivity is predicted to within 1 μΩ cm (2% relative error) and PT wall thickness within 0.03 mm (1% relative error) when each is the only extracted parameter. An excellent agreement between actual and predicted values of gap demonstrates the potential of the inverse algorithm for application to in-reactor gap measurement and simultaneous extraction of either PT wall thickness or resistivity when the other parameter is known. The extraction of PT resistivity may be particularly useful, as this parameter cannot otherwise currently be measured in-reactor.
Funder
Natural Sciences and Engineering Research Council of Canada
Subject
General Physics and Astronomy
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献