Monte Carlo model for evaluation of concentration of gold nanoparticle clusters as predictor of effective dose in proton therapy of microscopic tumors

Author:

Alanazi Nadyah1,Alanazi Reem12,Akhdar Hanan3ORCID,Alodhayb Abdullah1ORCID

Affiliation:

1. Department of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia

2. Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia

3. Department of Physics, College of Science, Imam Mohammad Ibn Saud Islamic University, Riyadh 11623, Saudi Arabia

Abstract

Radio-sensitization with gold nanoparticles (GNPs) is a relatively recent advancement of radiotherapy that is determined to increase radiation in the target tumor region. Monte Carlo (MC) simulation is a well-known method that has gained popularity by assisting in determining the effective dose in various tumors. Assessing the concentration of particles during proton therapy can provide the key to evaluating the efficiency of the performed treatment. Therefore, this study aimed to investigate the interconnection between the concentration of gold nanoparticle clusters and the dose enhancement in microscopic tumors by using the MC Model. A single cell tumor model with a size of 5  μm that was exposed to 100 MeV protons in a region resembling the human brain was investigated by using an MC simulation employing the Geant4 toolkit. With each nanoparticle having a diameter of 15 nm, a three-dimensional model of the random distribution of gold nanoparticle clusters was developed. Then, the dose enhancement for various concentrations of the GNPs accumulated around the tumor was estimated according to the dose enhancement factor (DEF), while the dose was concentrated on the surface of each GNP in the clusters. The results showed that the dose enhancement located at the Bragg-peak in the tumor region depended on the different concentrations of the GNPs. DEF values were found to be 1.016, 1.022, 1.026, 1.035, 1.013, 1.000, and 0.984 for the 1, 2, 3, 5, 10, 30, and 50 mg/ml concentration levels in water, respectively. The findings also revealed that large GNP clusters with high concentration levels yield larger DEFs than clusters with lower concentration levels, which may have an impact on radiation therapy. Specifically, at a concentration higher than 10 mg/ml, the estimated dose was significantly lower than those for a concentration of 5 mg/ml by about ∼100 mGy. As the benefit of the increased total dose must be balanced against the effect of the accumulation of nanoparticles, the current study detected dose reduction in regions that accumulate GNPs at high concentrations. As a result, the potential efficiency of the radiotherapeutic treatment can be reduced.

Funder

King Saud University

Publisher

AIP Publishing

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3