Fabrication of soft x-ray monolithic Wolter mirror based on surface scanning measurement using touch probe

Author:

Kume Takehiro1ORCID,Hiraguri Kentaro1ORCID,Imamura Yoichi1,Matsuzawa Yusuke1ORCID,Saito Takahiro1,Miyashita Hiroaki1,Takeo Yoko23ORCID,Senba Yasunori3ORCID,Kishimoto Hikaru3,Ohashi Haruhiko3ORCID,Hashizume Hirokazu1ORCID,Mimura Hidekazu4ORCID

Affiliation:

1. Technology Center, Natsume Optical Corporation, 1200-29 Kawaji, Iida, Nagano 399-2431, Japan

2. The Institute for Solid State Physics, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581, Japan

3. Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan

4. Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan

Abstract

The monolithic Wolter mirror is an ideal optical device for focusing soft x rays to a submicron-sized spot, with the advantages of high efficiency, large acceptance, achromaticity, and robustness to alignment error. The fabrication process for this type of mirror has not been established because of the difficulty in highly accurate figure measurement of free-form surfaces with small radii of curvature and steep profiles. In this study, we employed tactile scanning measurement for surface characterization to fabricate a high-precision Wolter mirror. First, it was demonstrated that the touch probe measurement did not leave scratches on the raw surface of the mirror substrate. Next, the measurement capability of the surface profiler was assessed, and the data analysis conditions were determined. Finally, the Wolter mirror was fabricated through repeated figure correction based on the tactile measurement, and the figure error of the final surface was evaluated. Wave-optical simulations that used this error as reference suggested that the size of the beam focused by the mirror was equivalent to the theoretical value at 1000 eV. The reflected image with uniform intensity distribution obtained at SPring-8 also revealed the effectiveness of the present fabrication approach based on tactile measurement.

Funder

Ministry of Education, Culture, Sports, Science and Technology

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3