Time-stretched multi-hit 3D velocity map imaging of photoelectrons

Author:

Goudreau E. Scott12ORCID,Boguslavskiy Andrey E.123,Moffatt Douglas J.2ORCID,Makhija Varun14ORCID,Hemsworth Michael1ORCID,Lausten Rune2,Marceau Claude2,Wilkinson Iain5ORCID,Stolow Albert1236ORCID

Affiliation:

1. Department of Physics, University of Ottawa 1 , Ottawa, Ontario K1N 6N5, Canada

2. National Research Council Canada 2 , Ottawa, Ontario K1A 0R6, Canada

3. Department of Chemistry, University of Ottawa 3 , Ottawa, Ontario K1N 6N5, Canada

4. Department of Physics, University of Mary Washington 4 , Fredericksburg, Virginia 22401, USA

5. Institute for Electronic Structure Dynamics, Helmholtz-Zentrum Berlin für Materialien und Energie 5 , Hahn-Meitner-Platz-1, D-14109 Berlin, Germany

6. NRC-uOttawa Joint Centre for Extreme Photonics 6 , Ottawa, Ontario K1A 0R6, Canada

Abstract

The 2D photoelectron velocity map imaging (VMI) technique is commonly employed in gas-phase molecular spectroscopy and dynamics investigations due to its ability to efficiently extract photoelectron spectra and angular distributions in a single experiment. However, the standard technique is limited to specific light-source polarization geometries. This has led to significant interest in the development of 3D VMI techniques, which are capable of measuring individual electron positions and arrival times, obtaining the full 3D distribution without the need for inversion, forward-convolution, or tomographic reconstruction approaches. Here, we present and demonstrate a novel time-stretched, 13-lens 3D VMI photoelectron spectrometer, which has sub-camera-pixel spatial resolution and 210 ps (σ) time-of-flight (TOF) resolution (currently limited by trigger jitter). We employ a kHz CMOS camera to image a standard 40 mm diameter microchannel plate (MCP)/phosphor anode detector (providing x and y positions), combined with a digitizer pick-off from the MCP anode to obtain the electron TOF. We present a detailed analysis of time-space correlation under data acquisition conditions which generate multiple electrons per laser shot, and demonstrate a major advantage of this time-stretched 3D VMI approach: that the greater spread in electron TOFs permits for an accurate time- and position-stamping of up to six electrons per laser shot at a 1 kHz repetition rate.

Funder

NRC CSTIP Quantum Sensors Program

RES’EAU-WaterNET

Canada Foundation for Innovation

NRC-uOttawa Joint Center for Extreme Photonics

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3