Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

Author:

Horvath L.1ORCID,Mauzey D.1ORCID,Bortolon A.1ORCID,Laggner F. M.2ORCID,Nagy A.1ORCID,Gerrú R.3ORCID,Kennedy J.4ORCID,Wilks T. M.3,Hughes J. W.3ORCID,Rosenthal A. M.3ORCID,Balbin-Arias J.5ORCID

Affiliation:

1. Princeton Plasma Physics Laboratory 1 , Princeton, New Jersey 08543, USA

2. Department of Nuclear Engineering, North Carolina State University 2 , Raleigh, North Carolina 27607, USA

3. MIT Plasma Science and Fusion Center 3 , Cambridge, Massachusetts 02139, USA

4. University of Florida 4 , Gainesville, Florida 32611, USA

5. The College of William and Mary 5 , Williamsburg, Virginia 23188, USA

Abstract

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ∼2.5 cm (FWHM) and an effective time resolution of ∼1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. The upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

Funder

Fusion Energy Sciences

Publisher

AIP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3