Photothermal vortex interferometer with azimuthal complex spectra analysis for the measurement of laser-induced nanoscale thermal lens dynamics

Author:

Dong Jingtao1ORCID,Zhang Tengda1,Yang Lei1ORCID,Zhang Yuzhong1ORCID,Lu Rongsheng1ORCID,Xie Xinglong2ORCID

Affiliation:

1. Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology 1 , Hefei 230009, Anhui, China

2. Key Laboratory of High-Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 2 , Shanghai 201800, China

Abstract

A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre–Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m−1 and D = 5.63 × 10−7 m2 s−1, respectively, which agree with the nominal ones of A0 = 0.129 m−1 and D = 5.17 × 10−7 m2 s−1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.

Funder

National Natural Science Foundation of China

Hefei Municipal Natural Science Foundation

China Scholarship Council

Open Foundation of Key Laboratory of High-Power Laser and Physics, Chinese Academy of Sciences

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3