Suppression of vortex rope formation and pressure fluctuation using anti-swirl fins in a Francis turbine model at part load condition with cavitation inception point

Author:

Shahzer Mohammad Abu12ORCID,Kim Seung-Jun2,Cho Yong3,Kim Jin-Hyuk12ORCID

Affiliation:

1. Convergence Manufacturing System Engineering (Green Process and Energy System Engineering), University of Science & Technology, 217 Gajeong-ro, Yuseong-gu, Daejeon 34113, South Korea

2. Carbon Neutral Technology R&D Department, Korea Institute of Industrial Technology, 89 Yangdaegiro-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do 31056, South Korea

3. K-water Convergence Institute, Korea Water Resources Corporation, 125 Yuseong16 daero 1689 beon-gil, Yuseong-gu, Daejeon 34045, South Korea

Abstract

Vortex rope formation at part load (PL) with cavitation inception causes pressure fluctuations inside the draft tube (DT) of a Francis turbine which may fail the turbine due to resonance and erosion. The pressure surge can be minimized by using anti-swirl fins which ensure safe turbine operation. The present study examines the effect of fin sizes and locations on the internal flow characteristics of the Francis turbine and predicts its adverse effect on the pressure surge. Three cases are investigated in which internal flow physics are compared among DTs with longer fins, shorter fins, and no fins. At the cavitation inception point under PL conditions, the characteristics are thoroughly studied numerically using ANSYS-CFX with structured and unstructured grids. Cavitation and PL conditions are designated by Thoma number 0.266 and guide vane angle [Formula: see text]. Numerical methodology is then verified by an experiment based on International Standard (IEC 60193). The vortex rope occurrence is suppressed using fins on the DT periphery and longer fins that are extended up to the elbow exhibit the lowest strength of the vortex rope. Maximum pressure recovery inside the DT is achieved using longer fins. The swirl intensity is remarkably reduced by about 94% with longer fins. The pressure peak of low frequency is about 60% suppressed using longer fins. The PL and cavitation-induced instabilities and vibrations are significantly mitigated by longer fins, while shorter fins also moderately minimize it. Hence, energy production is preferable with longer fins because of the safe and stable turbine function.

Funder

Korea Agency for Infrastructure Technology Advancement

Korea Institute of Industrial Technology

Publisher

AIP Publishing

Subject

Condensed Matter Physics,Fluid Flow and Transfer Processes,Mechanics of Materials,Computational Mechanics,Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3