Affiliation:
1. P. N. Lebedev Physical Institute , Leninskii Prospekt 53, Moscow 119991, Russia
Abstract
Charge-changing processes of low-charged ions, used in hydrogen plasma probing by the heavy ion beam probe method, are considered. Along with the ionization of beam ions by plasma electrons and protons, the charge-exchange processes of ions on H atoms and protons are also studied. It is shown that charge exchange of beam ions on plasma protons and H atoms, which is rarely taken into account, plays an important role in beam–plasma interaction. New data on the cross sections and rates of ionization and charge-exchange processes are presented for Tl+ and Tl2+ ions, which are frequently used for plasma diagnostics. Calculations are performed for hydrogen plasma temperatures Te = 1 eV–10 keV and densities Ne = 1012–1014 cm−3 at relatively low and high ion-beam velocities vb = 0.2 and 1.0 a.u., respectively. Special attention is paid to the determination of the electron temperatures at which the charge-exchange processes on H atoms and protons are important. Multiple ionization of beam ions by plasma electrons and protons is briefly discussed.
Subject
Electrical and Electronic Engineering,Nuclear Energy and Engineering,Nuclear and High Energy Physics,Atomic and Molecular Physics, and Optics