A 2–4 keV multilayer mirrored channel for the NIF Dante system

Author:

Rubery M. S.1ORCID,Ose N.1,Schneider M.1ORCID,Moore A. S.1ORCID,Carrera J.1ORCID,Mariscal E.1ORCID,Ayers J.1,Bell P.1,Mackinnon A.1ORCID,Bradley D.1ORCID,Landen O. L.1ORCID,Thompson N.1,Carpenter A.1,Winters S.1,Ehrlich B.1,Sarginson T.1,Rendon A.1,Liebman J.1,Johnson K.1,Merril D.1,Grant G.1,Shingleton N.1,Taylor A.1,Ruchonnet G.1,Stanley J.1,Cohen M.1,Kohut T.1,Issavi R.1,Norris J.1,Wright J.1,Stevers J.1,Masters N.1,Latray D.1,Kilkenny J.2,Stolte W. C.3ORCID,Conlon C. S.3,Troussel Ph.4ORCID,Villette B.4,Emprin B.4,Wrobel R.4ORCID,Lejars A.4,Chaleil A.4,Bridou F.5,Delmotte F.5ORCID

Affiliation:

1. Lawrence Livermore National Laboratory, P. O. Box 808, Livermore, California 94551-0808, USA

2. General Atomics, San Diego, California 92121, USA

3. MSTS, Mission Support and Test Services LLC, Livermore, California 94550-9239, USA

4. Commissariat à l’Énergie Atomique (CEA), DAM, DIF, F-91297 Arpajon, France

5. Laboratoire Charles Fabry, 2, Av. Augustin Fresnel, 91127 Palaiseau Cedex, France

Abstract

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100–200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel–ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2–4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2–4 keV spectral power with an uncertainty of ±8.7%.

Funder

National Nuclear Security Administration

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3