Fluorescence pressure sensors: Calibration of ruby, Sm2+: SrB4O7, and Sm3+: YAG to 55 GPa and 850 K

Author:

Wei Yingzhan1ORCID,Zhou Qiang1,Zhang Caizi1ORCID,Li Liang1ORCID,Li Xinyang1ORCID,Li Fangfei1ORCID

Affiliation:

1. Synergetic Extreme Condition User Facility, State Key Laboratory of Superhard Materials, College of Physics, Jilin University , Changchun 130012, China

Abstract

In this work, a calibration of ruby, samarium-doped strontium tetraborate (Sm2+: SrB4O7), and samarium-doped yttrium aluminum garnet (Sm3+: YAG) using Raman and fluorescence spectra was conducted within the temperature range of 296–850 K and pressure range of 0–55 GPa. The obtained calibration can be applied independently for high-temperature or high-pressure conditions and described as the unit form of P = (A′/B′) × [(λ/λT)B′ − 1] with A′ = A (296 K) + A1 × (T − 296) + A2 × (T − 296)2, B′ = B(296 K) + B1 × (T – 296), and λT = λT (296 K) + ΔλT, where the specific parameters are provided in the main text. It was observed that for the λ1 line (5D0 → 7F0 transition, about 685.2 nm under ambient conditions, also known as the 0-0 line) of Sm2+: SrB4O7, the neglect of the temperature effect on the pressure coefficient may lead to an underestimation of pressure above 35–40 GPa, with a maximum deviation of approximately 2.5 GPa within the range of 55 GPa and 850 K. For Sm3+: YAG, it may introduce significant errors under the whole high temperature and high pressure range if the effect of temperature is ignored, that is, about 3.9 GPa for Y1 line (4G5/2 → 6H7/2 transition, about 617.8 nm under ambient conditions) and 4.6 GPa for Y2 line (4G5/2 → 6H7/2 transition, about 616.0 nm under ambient conditions) at 850 K. Comparing the three fluorescence pressure sensors, the ruby has the strongest signal intensity and highest temperature sensitivity, and the Sm2+: SrB4O7 and the Sm3+: YAG possess lower temperature sensibility, wider used temperature range, and better spectral quality under high temperature and high pressure (HTHP), especially Sm2+: SrB4O7, which has a sharp high-intensity single peak λ1, perhaps the most promising sensor for high P–T experiments. Therefore, in view of the potential deflections of fluorescence peaks of each pressure sensor under HTHP, we recommend utilizing the HTHP-corrected relationships for pressure calibration.

Funder

National Natural Science Foundation of China

Jilin Provincial Scientific and Technological Development Program

Education Department of Jilin Province

Publisher

AIP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3