Affiliation:
1. First Light Fusion 1 , Yarnton, Oxfordshire OX5 1QU, United Kingdom
2. The Blackett Laboratory, Imperial College 2 , London SW7 2BW, United Kingdom
Abstract
A platform for flyer plate benchmarking experiments has been developed, with an external X-pinch driver for point projection radiography. The experiments were performed using CEPAGE, a low inductance pulsed power machine at First Light Fusion (2 MA, 1.4 µs), with a new vacuum transmission line and flyer load hardware designed specifically to give a line of sight for radiography. A broadband 10–20 keV x-ray source was produced by a portable X-pinch driver (140 kA, 350 ns) [Strucka et al., Matter Radiat. Extremes 7, 016901 (2021)] and was used to image the flyer. Radiography compliments the pre-existing diagnostic suite, which consists of current probes, velocimetry, and side-on optical probing of the impact shock transmitted into a transparent sample. The platform allows for significant insights into the 2D and 3D nature of the flyer launch, such as deformation and instability formation. It was used to diagnose a 10 × 9 × 1 mm3 aluminum flyer, which reached a peak velocity of 4.2 km s−1 before impact with a poly(methylmethacrylate) sample. The experimental configuration, on-shot source characterization, and the results from two flyer plate experiments on CEPAGE are discussed.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献