Affiliation:
1. University of Electronic Science and Technology of China, Chengdu 611731, China
2. Shanghai Space Propulsion Technology Research Institute, Shanghai 201109, China
Abstract
As high voltage pulse power capacitors, ceramic capacitors are widely used in high voltage pulse generators, trigger circuits, laser generators, and other fields. The capacitance of ceramic capacitors is closely related to the direct current (DC) bias voltage. However, the current capacitance measurement methods can only achieve a DC bias of 1 kV, which cannot meet the measurement requirements in high voltage environments. This paper proposes a capacitance measurement method that can accurately measure the capacitance under a DC bias of 3 kV. This method decouples the high DC bias voltage and high frequency alternating small signals and realizes low voltage calibration and high voltage isolation. The experimental results show that the proposed method measures the capacitance under a DC bias of 3 kV with a relative error within ±1%, which makes it possible to accurately quantify the capacitance hysteresis deviation in the process of increasing and decreasing back the voltage.
Funder
National Natural Science Foundation of China
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献