Affiliation:
1. Institute of Quantum Electronics, School of Electronics, Peking University 1 , Beijing 100871, China
2. Chengdu Synchronization Technology Ltd. 2 , Chengdu 611731, China
Abstract
We perform a new scheme of magnetic state selection in optically detected compact cesium beam clocks. Unlike the conventional method, we select atoms in the ground state |F = 4, mF ≠ −4⟩ by pointing the atomic collimator to the convex pole of the magnet realizing the two-wire magnetic field and detect atoms in |F = 3⟩ after interacting with the microwave field using a distributed feedback laser. The fluorescence background is greatly reduced as the inherent residual atoms |F = 4, mF = −4⟩ are avoided in this reversed scheme. The velocity distribution is narrowed, and the most probable velocity is decreased, since atomic trajectories are close to the weak-field region. We also investigate the relationship between the position of the atomic collimator and the distributions of the atomic beam, which is consistent with the Monte Carlo-based simulation model. By applying the reversed scheme and setting the deviated position of the collimator to 1.3 mm, the signal contrast is improved from 0.7 to 3, and the short-term frequency stability reaches 3.0 × 10−12 τ−1/2, nearly three times better than that of the high-performance version of Microsemi 5071A.
Funder
Joint Fund of the Ministry of Education of China
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Optically Pumped Cesium Beam Clock Using Monochromatic Light;2023 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS);2023-05-15