Improved calibration method for displacement transformation coefficient in optical and visual measurements

Author:

Li Haopeng1ORCID,Qiu Zurong1ORCID

Affiliation:

1. State Key Laboratory of Precision Measuring Technology and Instruments, School of Precision Instruments and Opto-electronics Engineering, Tianjin University , Tianjin 300072, China

Abstract

Optical and visual measurement technology is used widely in fields that involve geometric measurements, and among such technology are laser and vision-based displacement measuring modules (LVDMMs). The displacement transformation coefficient (DTC) of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process, and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view (FFOV). To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands, a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV. First, an image coordinate system, a pixel measurement coordinate system, and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM. In addition, marker spots in the FFOV are selected, and the DTCs at the marker spots are obtained from calibration experiments. Also, a fitting method based on locally weighted scatterplot smoothing (LOWESS) is selected, and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots. Finally, the calibrated distribution functions of the DTCs are applied to the LVDMM, and experiments conducted to verify the displacement measurement accuracies are reported. The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than ±15 µm and ±19 µm, respectively, and that for oblique displacement is better than ±24 µm. Compared with the traditional calibration method, the displacement measurement error in the FFOV is now 90% smaller. This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV, and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.

Publisher

AIP Publishing

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3