Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring

Author:

Mao Xiaopo1ORCID,Feng Zhiqiang1,Deng Xiaoguo2,Yu Zhijun3,He Dongsheng2

Affiliation:

1. State Grid Hubei Electric Power Co., Ltd., Electric Power Research Institute, Wuhan, Hubei 430077, China

2. State Grid Zhuzhou Power Supply Company, Zhuzhou, Hunan 412000, China

3. State Grid Enshi Electric Power Supply Company, Enshi, Hubei 445000, China

Abstract

In this paper, aiming at the application of geological disaster monitoring of transmission lines, by analyzing the data quality and positioning accuracy of Beidou original observation data, the influence of the electromagnetic environment of transmission lines on Beidou satellite monitoring data is obtained. According to the Beidou monitoring data of 500 kV transmission line for 23 days, the analysis results show that: in the case of strong electromagnetic interference/no electromagnetic interference, the difference of data integrity is less than 1%, the difference of multipath effect is less than 0.1 m, the difference of signal-to-noise ratio is less than 0.3 dB Hz, and the difference of cycle hop ratio is less than 150. The relative difference in positioning accuracy is less than 5%. In general, the electromagnetic environment of transmission lines has no significant impact on the data quality and positioning accuracy of Beidou deformation monitoring.

Funder

The State Grid Guide Project Under Grant

Publisher

AIP Publishing

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3