This paper proposes a new concept of phantom development, along with the utilization of new materials that can reproduce lung morphology and density. A lung substitute phantom using microspheres was fabricated; then, its dosimetric utility in radiotherapy was investigated, during which the density was adjusted to closely resemble the morphology of the actual human lung. Microspheres were used to reproduce alveoli, which are the main components of the lung. By changing the ratio of urethane, which is commonly used in soft tissue phantoms, to microspheres, we reproduced the density change of the lungs due to respiration. Here, we fabricated two slab-like lung substitutes to emulate commercially used phantoms. Although there is room for improvement in terms of practicality, the substitutes were easy to fabricate. Microscopic observation of the cut surface of the phantoms showed that the morphology of the phantoms mimicked the alveoli more faithfully than commercial phantoms. Furthermore, to compensate for the energy-independent mass attenuation and mass collision inhibition ability required by the tissue substitute phantom, we examined the physical properties of the phantom and confirmed that there was negligible energy dependence.

Funder

Japan Society for the Promotion of Science

Publisher

AIP Publishing

Subject

Instrumentation

Reference19 articles.

1. The Number of Alveoli in the Human Lung

2. 3D‐printable lung phantom for distal falloff verification of proton Bragg peak

3. Kyotokagaku brochure, Multipurpose Chest Phantom N1 “LUNGMAN,” Kyoto Kagaku Co., Ltd. 2022, pp. 22–24.

4. Phantom investigation of 3D motion-dependent volume aliasing during CT simulation for radiation therapy planning

5. Kyotokagaku brochure, Tough Phantom Series, Kyoto Kagaku Co., Ltd. 2022, pp. 49–50.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3