Abstract

Conductive rubber composites are mixtures of stretchable rubber and conductive materials. They can achieve conductivity and high elasticity and are used in soft robots and wearable devices. In general, these composites exhibit high electrical resistance owing to their bonds between the fillers breaking during elongation. However, there are several types of composite materials that decrease resistance by increasing contact between the conductive materials during elongation through optimization of the shape and size of the filler. These composite materials can rapidly decrease the resistance and are expected to be applicable to switch in electric circuits and sensors. However, to use such composite materials in circuits, the electrical resistance at the time of resistance reduction must be sufficiently low to not affect the electric circuit. To achieve this, a considerable amount of filler must be mixed; however, this reduces the elasticity of the composite. Simultaneously achieving elasticity of the composite and a sufficient decrease in the resistance is challenging. This study developed a conductive rubber composite gel by mixing silicone rubber, ionic liquid, and metal filler. Consequently, the composite achieved an elongation rate of over six times and a decrease in the resistance of less than 1/105. In addition, this composite material was used as a switch circuit wherein an electric circuit is turned on and off according to elongation through a connection to a DC power source.

Funder

Japan Science and Technology Agency

Precursory Research for Embryonic Science and Technology

Japan Society for the Promotion of Science

Publisher

AIP Publishing

Subject

Biomedical Engineering,Biomaterials,Biophysics,Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3