Mutually magnetically insulated two-species Brillouin flow

Author:

Darr Adam Michael1ORCID,Cartwright K. L.1ORCID

Affiliation:

1. Sandia National Laboratories , PO Box 5800, Albuquerque, New Mexico 87185, USA

Abstract

In this work, we use the Brillouin flow analytic framework to examine the physics of Magnetically Insulated Transmission Lines (MITL). We derive a model applicable to any particle species, including both positive and negative ions, in planar and cylindrical configurations. We then show how to self-consistently solve for two-species simultaneously, using magnetically insulated electrons and positive ions as an example. We require both layers to be spatially separated and magnetically insulated (mutually magnetically insulated); for a 7.5 cm gap with a 2 MV bias voltage, this condition requires magnetic fields in excess of 2.73 T. We see a close match between mutually insulated MITL performance and “superinsulated” (high degree of magnetic insulation) electron-only theory, as may be expected for these high magnetic fields. However, the presence of ions leads to several novel effects: (1) Opposite to electron-only theory, total electron currents increase rather than decrease as the degree of magnetic insulation becomes stronger. The common assumption of neglecting electrons for superinsulated MITL operation must be revisited when ions are present—we calculate up to 20× current enhancement. (2) The electron flow layer thickness increases up to double, due to ion space-charge enhancement. (3) The contributions from both ions and electrons to the MITL flow impedance are calculated. The flow impedance drops by over 50% when ions fill the gap, which can cause significant reflections at the load if not anticipated and degrade performance. Additional effects and results from the inclusion of the ion layer are discussed.

Funder

Sandia National Laboratories

Publisher

AIP Publishing

Subject

Condensed Matter Physics

Reference50 articles.

1. Saturn, a large area X-ray simulation accelerator,1987

2. The design of magnetically insulated transmission lines,2018

3. On the design of magnetically insulated transmission lines for z-pinch loads;Matter Radiat. Extremes,2019

4. Self-magnetically insulated transmission line (MITL) system design for the 20-stage HERMES-III accelerator

5. 100 years of the physics of diodes;Appl. Phys. Rev.,2017

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献